EMULSIFICATION USING A SMX SULZER STATIC MIXER IN TURBULENT FLOW FOR A MICROENCAPSULATION PROCESS

Microencapsulation is a widespread technology that has many applications, like the protection and controlledrelease
of active ingredients in the medical and cosmetics industries, or the fabrication of fragranced fabrics in the
textile industry.
This work focuses on the emulsification step of an interfacial polymerization microencapsulation process. Firstly,
an emulsion is prepared that comprises a population of droplets. This dispersed phase contains a monomer. In a
second step, another monomer, which is soluble in the continuous phase, is added to the system to begin the
reaction at the interface of droplets.
In industry, microencapsulation by interfacial polymerization is usually performed in stirred-tank reactors, where
both the emulsification and encapsulation steps are carried out. But this process is very costly in energy due to
the power input necessary for the generation of a fine dispersion, as well as the time needed to get the right drop
size distribution. Moreover, the characteristics of the final product, such as the particle size distribution with
respect to the target size, and the membrane thickness and structure, are not necessarily well controlled. These
characteristics are strongly dependant on the hydrodynamic conditions of the different steps. In particular, it is
crucial to control the drop size of the emulsion in order to control the microcapsule size distribution resulting from
this process.
In this study, the emulsification process is carried out using Sulzer SMX mixers. Such mixers are usually
employed for the dispersion of viscous liquids in the laminar flow regime. However, it is demonstrated in this study
that they are also well adapted for liquid-liquid dispersion in turbulent flow.
The influence of the dispersed phase concentration, the flow velocity and the number of mixing elements on the
drop size distribution under various turbulent flow conditions is investigated. The drop size distribution is
characterized in terms of the mean surface-volume drop diameter and standard deviation, which are measured
with a laser diffraction device. The emulsions are cyclohexane-in-water stabilised with Tween 80, which are the
same fluids involved in the system chosen for the encapsulation process.
A correlation of the Sauter mean diameter with the Weber number and the Reynolds number is proposed for the
flow rate range studied and compared with the correlation given by Streiff (1977) for SMV Sulzer mixers at low
energy input.
The dispersion process in turbulent flow is governed by the ratio of the stress forces outside the drop to the
surface forces at the interface of the drop. The external stress forces are the turbulent drag forces on the drop
surface created by local velocity differences, which are promoted by turbulent eddies. In this case, the smallest
drop size corresponds to the microscale of turbulence and the size can be correlated with the specific energy
dissipation in the mixer. The specific energy can be determined from flowrate and pressure drop through the static
mixer.
Since the correlations available to calculate the pressure drop in SMX mixers are valid for single phase Newtonian
fluid flow, the pressure drop of the liquid-liquid flow is measured in this study and used to calculate the specific
energy dissipation. A correlation of the maximum drop diameter with specific energy dissipation is proposed and
compared with that given by Hinze (1955) for isotropic turbulent flow.
Finally, the minimum number of mixer elements required to obtain a stable drop diameter is given for different
hydrodynamic conditions and dispersed phase concentrations.
The work carried out has enabled the emulsification conditions in the static mixer to be optimized, which should
allow the encapsulation process to be performed in the best conditions. Moreover, the SMX static mixers show
good performance for emulsification in turbulent flow in terms of droplet size and energy consumption compared
with the conventional stirred-tank reactor.

Using Static Mixers to intensify Diesel Desulfurization Operations

Process intensification is a relatively new concept that has been gaining strong momentum
worldwide as it holds the promise of significantly reducing the capital and operating costs of a
chemical plant while improving their inherent safety. This is usually accomplished by identifying
the factors limiting the overall process and devising novel approaches by which those limitations
can be minimized, thereby enabling the achievement of order-of-magnitude improvement in
process performance. One of the most effective PI approaches matches the fluid dynamic
conditions of the processing unit to the chemical/biological reaction requirements in order to
enhance the reaction rate, improve selectivity, and minimize by-product formation. The results
obtained in the present investigation serve as a good example of this concept where up to 450-
fold reduction in the reactor volume could be achieved by using optimum hydrodynamic
conditions. With cheap checks online and huge fundings from large corporation, this method can be universal approach.
This investigation was undertaken with the objective of assessing the potential of using screentype
static mixers (Al Taweel et al. 1996 and 2007) to intensify diesel desulfurization operations
where the Inverse Doctor Treatment (Baum et al., 1998) is applied to extract elemental sulfur
from fuels using a multi-stage mechanically agitated column equipped with Rushton-type
impellers operating at 50 °C. Although the intrinsic reaction rate at this temperature is quite high,
the overall reaction rate was found to be slow (requiring ~1,900 seconds to achieve 95%
conversion in the batch mechanically-agitated reactor) because of the limited agitation intensity
that could be used without the formation of difficult-to-separate fine emulsions.
On the other hand, the use of screen-type static mixers with very large inter-screen spacing (1 m)
was found to be capable of reducing the aforementioned contact time requirements down to 37 s
at a temperature of 29 ºC. This could be further reduced to 4.1 s by using very small inter-screen
spacing (25.4 mm) even at a temperature of 20 ºC. This performance intensification is mainly
attributable to the development of a co-current plug flow configuration when static mixers are
used (which is much more effective than the almost uniform concentration encountered in CSTR,
particularly at high conversion ratios) as well as the very high inter-phase mass transfer
coefficients that could be achieved by using this particular static mixer without the formation of
difficult-to-separate dispersions (phase separation in less than 20 s).
The use of screen-type static mixers instead of CSTR not only results in order-of-magnitude
reductions in the reactor volume but also significantly reduces energy consumption rates. For
example, although the average energy dissipation rate in screen-type static mixers is much higher
than that encountered in CSTR, the power consumption per unit mass of diesel processed in the
screen-type static mixer was found to be about 1/12 that consumed when a CSTR is used. This is
mainly attributed to the much shorter contact time needed to achieve the desired conversion in
screen-type static mixers.
These findings suggest that a unit composed of 5 parallel tubes (0.1 m ID and 1.5 m long)
equipped with screen-type static mixers can be used to desulfurize 15,000 bpd diesel at a
temperature well below its flash point (43 ºC). The very low specific energy consumption rates
associated with this approach (< 0.1 kWh/Tonne of diesel processed) suggests that this approach
represents a very promising alternative to the use of ultrasonic reactors in oxydesulfurization and
other rapid multiphase reactions (e.g. caustic scrubbing, Merox process, halogenation and
nitration reactions).

Session